3.0/3 Ton Vertical Geothermal Heat Pump EER 23.5
Original price was: $3,399.00.$3,299.00Current price is: $3,299.00.
Unit Model HPX036VSS
3.0/3 Ton Vertical Geothermal Heat Pump EER 23.5
AHRI#4547871
- Description
- FEATURE INFORMATION
- UNIT PERFORMANCE
- BLOWERS
- CONDENSORS
- COMPRESSOR
- GENERAL
Description
3.0/3-Ton Vertical Geothermal Heat Pumps That Are Right for You
Get a 3.0 or 3-ton Vertical Geothermal Heat Pump with a 23.5 EER, a Stainless-Steel Cabinet, a Drain Pan, and a Variable Speed Fan Motor. Look under the product tab on our website, Miamihp.com, for more specific information.
One of the geothermal products made by Miami Heat Pump is a 3-ton vertical geothermal heat pump. The highest caliber geothermal heat pumps are a prime illustration of our designing, manufacturing, and engineering for both industrial and domestic uses.
No matter if you live in harsh summer or winter climates, our heat pumps can meet all of your heating and cooling requirements. Our geothermal heating pumps can be used for more than just cooling and heating; they are also dependable and energy-efficient.
Why is Miami’s 3.0-ton vertical geothermal heat pump the USA?
Unexpected Energy Efficiency: You can reduce your yearly heating and cooling costs by up to 70% by using Miami heat pump geothermal systems. You can cool or heat your home using the earth’s and atmosphere’s natural energy; geothermal systems provide up to four units of energy for each unit you purchase.
Greater Comfort: Miami heat pumps are made with a long lifespan in mind and are incredibly dependable. The best dehumidification when cooling and balanced humidity when warm are provided by Miami heat pumps, making them the most comfortable choice for homes or businesses. Unwind in your own house without using electricity or paying for it.
How does a 3.0-ton Vertical Geothermal Heat Pump work?
In places with limited space, like offices, schools, and commercial buildings, vertically closed loop systems are common. In essence, installing a horizontal loop is not possible due to the size of the land. Since they have less of an impact on landscaping, vertical closed loops are also used in places where the soil is too shallow for trenching. For this type of geothermal heat pump, two vertical loops bent into a U-shape are inserted into tiny holes dug into the ground (four inches in diameter, 100 to 400 feet deep, and spaced two feet apart). Then, horizontal loops are used to join these vertical loops together.
A 3.0-ton vertical geothermal heat pump’s price
According to the Environmental Protection Agency (EPA), installing geothermal heat pumps can help property owners save up to 50% on cooling costs and up to 70% on heating costs each year. Given this level of energy savings, geothermal systems typically have payback periods of between 5 and 7 years, making GSPHs an excellent long-term financial investment.
Benefits provide by vertical 3.0-ton geothermal heat pump
The temperature is higher because more heat is absorbed than with a horizontal sensor method. Every 100m, it rises from 2-4 Co. It is the geothermal system that is used the most, with a usage rate of 82.9%.
To install a U-shaped loop of high-density polyethylene, holes with a diameter of 13 cm and a depth of 150 m are drilled for this type. Propylene glycol is typically used as the heat transfer fluid inside of this. Additionally, the loop is submerged in grout-like bentonite to improve heat transmission.
Some advantages are given below:
- Less ground clearance is offered by vertical boreholes than by horizontal ones.
- This system works flawlessly with a floor heating scheme.
- It makes use of the “free” renewable energy that the earth provides.
- It drastically lowers heating expenses.
- It enables the system to be used in conjunction with a domestic hot water tank or an in-ground pool heater.
- In cities, this form of geothermal energy can be used more readily.
Save money with a 3.0-ton vertical geothermal heat pump: Buy now!
A 3.0-ton vertical geothermal heat pump system will typically save you money over time, but the installation costs can be a little intimidating upfront. Understanding the rebates and incentives that are available to you can help you decide if geothermal energy is something you want to invest in if you are worried about the cost. The International Ground Source Heat Pump Association (IGSHPA) claims that GSHPs can reduce heating and cooling expenses by up to 50% when compared to traditional fossil fuel systems. The Department of Energy estimates their payback period to be 5 to 10 years. Contact us today!
FEATURE INFORMATION
FEATURE INFORMATION | ||||
---|---|---|---|---|
CABINET- | Stainless Steel, Insulated Evaporator Section, Access Panels | |||
DRAIN PAN- | Stainless Steel, Insulated | |||
SAFETY- | High/Low Press, Switches, Condensate Over Flow Switch, Overload Protection, AntiShort Cycle Relays, Lock Out Relays | |||
BLOWERS- | Centifugal Galvanized Wheel, X13 ECM Motor | |||
REF CIRCUITS- | Thermal Expension Valve 1 Circuit | |||
COND COIL- | Coaxial Cupronickel Heat Exchanger | |||
EVAP COIL- | Copper Tubes, Alumininium Fins | |||
REFRIGERANT- | R-410A |
UNIT PERFORMANCE
UNIT PERFORMANCE | ||||||
---|---|---|---|---|---|---|
EVAP COOLING CAPACITY – BTU/HR | WLHP36,000 | GWHP 40,000 | GLHP 36,500 | |||
HEATING CAP. – BTUIHR (HEAT PUMP MODE) | WLHP 40,000 | GWKP 32,000 | GLHP 26,000 | |||
FACE VELOCITY – FPM | 332 | |||||
COIL ENTERING AIR TEMP. DB/WB- F | 80.6/66.2 |
BLOWERS
BLOWERS | ||||||
---|---|---|---|---|---|---|
AIR VOLUME – CFM | 1200 | |||||
ESP-INH2O | 0.65 | |||||
BLOWER SIZE & QTY | 10”x7” / 1 | |||||
FAN MOTOR-HP&QTY | 3/4 / 1 | FLA(EA)= 6.0A |
CONDENSORS
CONDENSORS | ||||||
---|---|---|---|---|---|---|
WATER FLOW – GPM | 9.0 | |||||
ENTERING WATER TEMP. °F | WLHP 86.0 | GWHP 59.0 | GLHP 77.0 | |||
WATER PRESS. DROP – FT H2O | 11.7 |
COMPRESSOR
COMPRESSOR | ||||||
---|---|---|---|---|---|---|
NO. OF CIRCUIT CAPACITY STEPS | 1/1 | |||||
TYPE & OTY | Scroll/1 | RLA(EA)= 16.8 A | LRA(EA)=79.0 A |
GENERAL
GENERAL | ||||||
---|---|---|---|---|---|---|
VOLTAGE RATING I PHASE / HERTZ | 230/1/60 | |||||
E.E.R. | WLHP 16.0 | GWHP 23.5 | GLHP 17.9 | |||
C.O.P (HEAT-PUMP ONLY) | WLHP 4.8 | GWHP 4.2 | GLHP 3.6 | |||
MIN AMP. / MAX FUSE – AMPS. | 27/40 | |||||
DIMENSION W” X L X H” | 21.5” X 21.5” X 39” | |||||
WEIGHT – NET – LBS. | 220 | |||||
WATER CONNECTION SIZE | 3/4 | |||||
DRAIN CONNECTION SIZE | 3/4 |