Sale!

4.0/4 Ton Vertical Geothermal Heat Pump EER 27.0

Original price was: $4,199.00.Current price is: $3,949.00.

Unit Model HPX048VSS

4.0/4 Ton Vertical Geothermal Heat Pump EER 27.0

AHRI#4547874

Product total
Options total
Grand total
Product price:$3,949.00
Total options:
Order total:
  • Description
  • FEATURE INFORMATION
  • UNIT PERFORMANCE
  • BLOWERS
  • CONDENSORS
  • COMPRESSOR
  • GENERAL

Description

4-ton Vertical Geothermal Heat Pump Overview

A fantastic and effective technology that can be used for both heating and cooling purposes is the use of the natural heat energy from the earth’s surface for heat transfer. Exchange systems, coupled heat pumps, and geothermal heat pumps are all names for this technology that are frequently used to refer to geothermal heat pump systems. These heat pumps are the most energy-saving technology for residential and commercial uses, according to the United States Department of Energy. When used properly, the 4.0 and 4-Ton vertical geothermal heat pump with an EER of 27.0 and other types of heat pumps can reduce electrical consumption by up to 80%. These mechanical products are also powered by renewable energy. Only this technology can meet both financial and energy-saving aspects.

A 4-ton Vertical Geothermal Heat Pump: How Does It Work?

Vertical systems are frequently used in substantial commercial structures and educational institutions because horizontal loops require an excessive amount of land. Because they cause the least disruption to the existing landscaping, vertical loops are also used when the soil is too shallow for trenching. For a vertical system, holes are drilled between 20 and 400 feet deep, with a diameter of roughly four inches. placing two pipes inside the hole, creating a loop at the bottom by grouting them together, and improving performance. The horizontal pipe connects the vertical loops, which are also known as the manifold, trenches, horizontal pipe, and the building’s heat pump.

Application of a 4-ton vertical geothermal heat pump

Large commercial buildings and educational institutions frequently use these systems because horizontal loops would require prohibitive amounts of land. Because they cause the least amount of disruption to the existing landscaping, vertical loops are also used when the soil is too shallow for trenching.

Will the price of energy drop with a geothermal heat pump?

Your heat pump’s design and operation will have an impact on operating costs. How much money you save on energy costs depends on the system you replace. the annual cost savings of installing a typical ground source heat pump in a typical four-bedroom home, taking into account any recommended radiator upgrades.

Does using geothermal energy require laborious upkeep?

The truth is that while all mechanical systems eventually require some maintenance, geothermal systems typically have fewer components than conventional heating and cooling systems. As a result, fewer parts can fail or need to be replaced. Geothermal systems are therefore incredibly dependable and typically require less maintenance than many other types of home heating and cooling systems.

Features of 4.0-ton vertical geothermal heat pump

The following characteristics of the heat pumps:

  • Additional heat lockout
  • Digital thermostats
  • Controlled staged supplemental heat
  • An emergency heat signal
  • Safety controls
  • Accumulator
  • Crankcase heater, filter
  • Models for salt air

Buy a 4.0/4 Ton Vertical Geothermal Heat Pump EER 27.0 at Miamihp

Vertical Geothermal Heat Pumps of 4.0 and 4-ton vertical geothermal heat pump EER of 27.0 is a cost-effective and energy-efficient way to heat, cool, or refrigerate any conditioned enclosure. The earth’s surface can absorb almost infinite amounts of heat, and the temperature below the surface never rises above a comfortable level. This heat pump can absorb or release heat as needed. This heat pump‘s key feature is its ability to heat water for domestic use to 120 degrees Fahrenheit while refrigerating to temperatures below zero. The best option for large buildings’ heating and cooling needs is geothermal heat pumps, which are available for both commercial and residential use.

Vertical Geothermal Heat Pump for Homes

By extracting heat energy and transferring it into buildings, geothermal heating and cooling systems reduce heating and cooling costs by between 50 and 60%, depending on the fuel being compared.

Similar to traditional air conditioning during the summer, geothermal cooling works by storing heat deep within the earth for future use. Since the heat extracted during the summer warms the earth’s core, the ground source heat pump’s efficiency during the winter is increased. the result is guilt-free air conditioning.

Buy a 4-ton vertical geothermal heat pump with a variable-speed fan motor, a stainless steel cabinet, and a drain pan. Look under the product tab on our website, Miamihp.com, for more detailed information. For more information, call 866-407-8535.

FEATURE INFORMATION

FEATURE INFORMATION
CABINET-Stainless Steel, Insulated Evaporator Section, Access Panels
DRAIN PAN-Stainless Steel, Insulated
SAFETY-High/Low Press, Switches, Condensate Over Flow Switch, Overload Protection, AntiShort Cycle Relays, Lock Out Relays
BLOWERS-Centifugal Galvanized Wheel, X13 ECM Motor
REF CIRCUITS-Thermal Expension Valve 1 Circuit LOWERS – Centifugal Galvanized Wheel, X13 ECM Motor
COND COIL-Coaxial Cupronickel Heat Exchanger
EVAP COIL-Copper Tubes, Alumininium Fins
REFRIGERANT-R-410A

UNIT PERFORMANCE

UNIT PERFORMANCE
EVAP COOLING CAPACITY – BTU/HRWLHP 51,000GWHP 57,000GLHP 53,300
HEATING CAP. – BTUIHR (HEAT PUMP MODE)WLHP 58,000GWKP 50,000GLHP 39,000
FACE VELOCITY – FPM281
COIL ENTERING AIR TEMP. DB/WB- F80.6/66.2

BLOWERS

BLOWERS
AIR VOLUME – CFM1600
ESP-INH2O0.75
BLOWER SIZE & QTY10”x10” / 1
FAN MOTOR-HP&QTY3/4 / 1FLA(EA)= 6.0 A

CONDENSORS

CONDENSORS
WATER FLOW – GPM12.0
ENTERING WATER TEMP. °FWLHP 86.0GWHP 59.0GLHP 77
WATER PRESS. DROP – FT H2O0

COMPRESSOR

COMPRESSOR
NO. OF CIRCUIT CAPACITY STEPS1/1
TYPE & OTYScroll/1RLA(EA)= 24.3 ALRA(EA)=117.0 A

GENERAL

GENERAL
VOLTAGE RATING I PHASE / HERTZ230/1/60
E.E.R.WLHP 18.0GWHP 27.0GLHP 20.0
C.O.P (HEAT-PUMP ONLY)WLHP 5.0GWHP 4.3GLHP 3.6
MIN AMP. / MAX FUSE – AMPS.36/50
DIMENSION W” X L X H”26” X 24” X 43”
WEIGHT – NET – LBS.320
WATER CONNECTION SIZE1
DRAIN CONNECTION SIZE3/4

Contact us now to get quote

Contact us now to get quote

Contact Us

customerservice@miamihp.com
1420 NW 2nd. Ave. Boca Raton, Fl 33432

Follow Us On Social